Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data

Data source

Reference
Reference Type:
other: Substance Database
Title:
GESTIS Substance database
Author:
IFA Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung

Materials and methods

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Vapour pressureopen allclose all
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
16 hPa
Test no.:
#2
Temp.:
50 °C
Vapour pressure:
75 hPa
Test no.:
#3
Temp.:
65 °C
Vapour pressure:
125 hPa

Applicant's summary and conclusion

Conclusions:
Vapour pressure: 16 hPa at 20°C