Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 03/16/2016 - Experimental Completion Date: 03/16/2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
other: not specified
Specific details on test material used for the study:
Test Item: FAT 92504/C TE
Lot. BOP 01-15
Mass median aerodynamic diameter:
15.904 µm
Key result
Percentile:
other: L50
Mean:
15.904 µm
Remarks on result:
other: No standard deviation
Key result
Percentile:
other: L10
Mean:
3.049 µm
Remarks on result:
other: No standard deviation
Key result
Percentile:
other: L90
Mean:
36.005 µm
Remarks on result:
other: No standard deviation
Remarks on result:
other: Not measured
Conclusions:
The median diameter of partcle size distribution was 15.904 μm.
Executive summary:

The particle size distribution for FAT 92504/C TE was assessed in a study conducted using the laser diffraction methods described in guidelines CIPAC MT 187 and ISO 13320-1. Based on the findings of the study, following results were obtained:

L10: 3.049 μm

L50: 15.904 μm

L90: 36.005 μm

Description of key information

The particle size distribution for FAT 92504/C was assessed in a study conducted using the laser diffraction methods described in guidelines CIPAC MT 187 and ISO 13320-1. Based on the findings of the study, following results were obtained:

L10: 3.049

L50: 15.904 μm

L90: 36.005 μm

Additional information