Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Expermental Completion Date: 02/10/2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Findings:

Safety Pre-Test:

- A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test:

- The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
FAT 92504/C should be considered as not highly flammable.
Executive summary:

The flammability potential of FAT 92504/C was assessed in accordance with EU Method A.10. During the preliminary test, the test item was formed into an unbroken strip or powder train about 250 mm long and observed for propagation by burning with flame. If propagation over 200 mm of the train occurs within 2 minutes, then a full test program to determine the burning rate is required. With FAT 92504/C, glowing was observed during heating, but no ignition occurred within two minutes. Hence, the test item FAT 92504/C should be considered as not highly flammable!

Description of key information

The flammability potential of FAT 92504/C was assessed in accordance with EU Method A.10. During the preliminary test with FAT 92504/C, glowing was observed during heating, but no ignition occurred within two minutes. Hence, the test item FAT92504/C should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

FAT 92504/C was found to be not flammable, hence does warrant classification as per the Regulation (EC) No. 1272/2008.