Registration Dossier

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08.-17.10.2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU and OECD guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 105 (Water Solubility)
GLP compliance:
no
Type of method:
column elution method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Water solubility
Water solubility:
< 0.014 mg/L
Temp.:
20 °C
Remarks on result:
other: pH not relevant

Applicant's summary and conclusion

Executive summary:

The water solubility of the test item was below 0.014 mg/L.