Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22.-30.07.2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU and OECD guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
no
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
0 Pa
Temp.:
25 °C
Vapour pressure:
0 Pa
Temp.:
50 °C
Vapour pressure:
0.001 Pa

Applicant's summary and conclusion

Executive summary:

The vapour pressure of the test item was 5*10 -5 at 25°C.