Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13.-25.09.2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU and OECD guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Boiling point
Boiling pt.:
> 500 °C
Atm. press.:
1 013.25 hPa
Decomposition:
no

Applicant's summary and conclusion

Executive summary:

The boiling point of the test substance was > 500°C.