Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1991

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
Not available

Results and discussion

Flammable solids
Key result
Test procedure:
other: EU Method A10
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

Highly flammable: No

Pyrophoric substance (A13): No

Highly flammable solid (A10): No

In contact with water substance liberates highyl flammable gases (A12): No

A12/A13 tests were not conducted as experience in use indicates that results would be negative.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test material was determined to be not highly flammable.