Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
no data
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
The study was performed according to a valid guideline without any deviations and was conducted under GLP conditions. Furthermore, the data were submitted by another legal entity, under Directive 67/548/EEC, at least 12 years previously. The registrant has been granted permission to use the information, which has been extracted from the ECHA databases, for REACH registration purposes. No full information related to the experimental result are available but these deficiencies do not affect the quality of the relevant results.
Qualifier:
according to
Guideline:
other: 92/69/EEC, A1 (DSC method-ASTM E537-86)
Deviations:
not specified
GLP compliance:
yes
Type of method:
thermal analysis
Key result
Melting / freezing pt.:
> 360 °C

no data

Conclusions:
The substance is a solid up to more than 360 °C.
Executive summary:

The melting point of the test material was determined in a study which was conducted under GLP conditions and in accordance with the standardised guideline EU Method A.1.

Under the test conditions, the melting point of the substance was determined to be > 360 °C.

Description of key information

The substance is a solid up to more than 360 °C.

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
360 °C

Additional information

no data