Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-02-09 – 2017-02-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental result performed using standard methods of analysis
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Principles of method if other than guideline:
The density is calculated from the difference in weight between the full and empty pycnometer and its volume
GLP compliance:
no
Type of method:
pycnometer method
Specific details on test material used for the study:
- Name of test material (as cited in study report):Aluminium tristearate- Molecular formula :C18H36O2.1/3Al- Molecular weight: 877.3995 g/mol- Substance type:Organic- Physical state:Solid
Key result
Type:
density
Density:
1.066 g/cm³
Temp.:
20 °C

Method Details

Observations

Remarks if, any

Guideline

OECD 109

1stReading

2nd Reading

 

 

 

Method

Adapted from ASTM 854-02

 

 

 

Principle of method

The density of test item is determined by using pyknometer. It is the ratio of mass of the unit volume of test item at a stated temperature to mass of the same volume of gas free distilled water at a stated temperature.

 

 

 

Test temperature (°C)

-

20oC

20oC

 

Atmospheric pressure (in hPa)

-

976.8

975.8

 

Weight of empty dry pyknometer (Wp)

 

31.234

29.214

 

Weight of pyknometer filled with water (WA)

 

81.374

79.891

 

Weight of pyknometer + test Item (WPS)

 

36.274

34.231

 

Weight of pyknometer +test Item+ water (WB)

 

81.974

79.791

 

 

 

CALCULATIONS:

 

Calculated values

1st Calculation

2nd Calculation

 

Wo=WPS-WP

 

5.040

 

5.017

 

(WA-WB)

 

-0.600

 

-0.100

 

Specific gravity = WO/[WO+ (WA-WB)]

5.040/[5.440-0.600]

5.017/[5.017-0.100]

 

Specific Gravity; Gs

1.135*0.9982

1.001*0.9982

Density (g/cm³)

1.133

0.9991

Mean Density (g/cm³)

1.066

Conclusions:
The density of substance Aluminium tristearate (CAS No. 637-12-7)was determined following OECD Guideline 109 and according to the Adapted from ASTM D854-02 using glass pyknometer .The mean density of test item is was found to be1.066 g/cm³at 20°C and 975.85 hP.
Executive summary:

The density of substance Aluminium tristearate (CAS No. 637-12-7)was determined following OECD Guideline 109 and according to the Adapted from ASTM D854-02 using glass pyknometer .The mean density of test item is was found to be1.066 g/cm³at 20°C and 975.85 hP.

Description of key information

The density of substance Aluminium tristearate (CAS No. 637-12-7)was determined following OECD Guideline 109 and according to the Adapted from ASTM D854-02 using glass pyknometer .The mean density of test item is was found to be1.066 g/cm³at 20°C and 975.85 hP.

Key value for chemical safety assessment

Relative density at 20C:
1.066

Additional information

The density of substance Aluminium tristearate (CAS No. 637-12-7)was determined following OECD Guideline 109 and according to the Adapted from ASTM D854-02 using glass pyknometer .The mean density of test item is was found to be1.066 g/cm³at 20°C and 975.85 hP.

Other supporting studies from reliable sources such as authoritative database and handbook suggests that the density of chemical Aluminium tristearate was determined to be in the range of 1.01 g/cm3 to 1.070 g/cm3.

As the data from lab has K1 reliability and the test was performed using OECD guidelines which has the value of density as 1.066 g/cm3 at 20 degree C, thus considered as key study for the chemical safety assessment