Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental Starting Date: 03 September 2012; Experimental Completion Date: 07 January 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Test material form:
other: solid

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
505 s
Remarks on result:
other: Combustion was propagated over 200mm in 8 minutes 25 seconds.

Any other information on results incl. tables

The ‘rope’ melted and ignited with an orange flame which produced grey smoke and soot and left black charred remains. Combustion was propagated over 200mm in 8 minutes 25 seconds.

 

The result of the preliminary screening test obviated the need to perform the main test.

 

Applicant's summary and conclusion

Interpretation of results:
other: not highly flammable.
Conclusions:
The test item has been determined to be not highly flammable as it did not propagate combustion over the 200 mm of the preliminary screening test in under 4 minutes.
Executive summary:

Method

The flammability (solids) was determined by measuring the burning rate of test item prepared as a ‘rope’ of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Results

The ‘rope’ melted and ignited with an orange flame which produced grey smoke and soot and left black charred remains. Combustion was propagated over 200mm in 8 minutes 25 seconds.

 

The result of the preliminary screening test obviated the need to perform the main test.

The test item has been determined to be not highly flammable as it did not propagate combustion over the 200 mm of the preliminary screening test in under 4 minutes.