Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-10-21
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Determination has been run according to standardized method, no GLP compliance.
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Key result
Flash point:
154 °C
Atm. press.:
ca. 1 atm
Conclusions:
The flash point is determined to 154 ºC.

Description of key information

The flash point is determined to 154 ºC.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
154 °C

Additional information