Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study under GLP conditions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-methylbenzene-1,4-diyl bis{4-[4-(acryloyloxy)butoxy]benzoate}
EC Number:
700-238-1
Cas Number:
132900-75-5
Molecular formula:
C35H36O10
IUPAC Name:
2-methylbenzene-1,4-diyl bis{4-[4-(acryloyloxy)butoxy]benzoate}
Constituent 2
Reference substance name:
4-({4-[4-(Acryloyloxy)butoxy]benzoyl}oxy)-2-methylphenyl 4-[4-(acryloyloxy)butoxy]benzoate
IUPAC Name:
4-({4-[4-(Acryloyloxy)butoxy]benzoyl}oxy)-2-methylphenyl 4-[4-(acryloyloxy)butoxy]benzoate
Details on test material:
Batch PC5
Purity: 97.9 %

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Preliminary test:

The test item melted at contact with a flame but could not be ignited with a flame.

A main test was therefore not necessary.

Applicant's summary and conclusion

Conclusions:
The test item is not a highly flammable solid in the sense of the consolidated version of Council Directive 67/548/EEC Annex V, Method A.10 (Council Directive 92/69/EEC).