Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2002
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods

Data source

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Anexo V.A.2 del Reglamento sobre Notificacion de Sustancias Nuevas y Clasificacion, Envasado y Etiquetado de Sustancias Peligrosas
Type of method:
HPLC method

Test material

Constituent 1
Chemical structure
Reference substance name:
11-(chloroacetyl)-5,11-dihydro-6H-pyrido[2,3-b][1,4]benzodiazepin-6-one
EC Number:
249-227-9
EC Name:
11-(chloroacetyl)-5,11-dihydro-6H-pyrido[2,3-b][1,4]benzodiazepin-6-one
Cas Number:
28797-48-0
Molecular formula:
C14H10ClN3O2
IUPAC Name:
11-(chloroacetyl)-5,11-dihydro-6H-pyrido[2,3-b][1,4]benzodiazepin-6-one
Test material form:
solid

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Key result
Type:
log Pow
Partition coefficient:
0.5
Remarks on result:
other:
Remarks:
no pH value and temperature are provided

Applicant's summary and conclusion

Conclusions:
Para comparar el coeficiente de reparto con el maximo de sustancias, seconsidera valido el resultado de log P = 0,5 obtenido en el analisisrealizado con la fase movil de metanol:agua, ya que esta condicion escomun a todas las sustancias evaluadas.