First-aid measures

Inhalation: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
Get medical attention if symptoms occur.
Ingestion: Wash out mouth with water. Remove victim to fresh air and keep at rest in a
position comfortable for breathing. If material has been swallowed and the exposed
person is conscious, give small quantities of water to drink. Do not induce vomiting
unless directed to do so by medical personnel. Get medical attention if symptoms
occur.
Skin contact: Flush contaminated skin with plenty of water. Remove contaminated clothing and
shoes. Get medical attention if symptoms occur.
Eye contact: Immediately flush eyes with plenty of water, occasionally lifting the upper and lower
eyelids. Check for and remove any contact lenses. Get medical attention if irritation
occurs.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media: In case of fire use water spray(fog), foam, dry chemical or CO2.
Unsuitable extinguishing media: none known
Special hazards arising from the substance or mixture
Hazards from the substance or mixture: No specific fire or explosion hazard.
Hazardous thermal decomposition products: No specific data.
Advice for firefighters
Special protective actions for fire-fighters: Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without
suitable training.
Special protective equipment for fire-fighters: Fire-fighters should wear appropriate protective equipment and self-contained
breathing apparatus (SCBA) with a full face-piece operated in positive pressure
mode. Clothing for fire-fighters (including helmets, protective boots and gloves)
conforming to European standard EN 469 will provide a basic level of protection for
chemical incidents.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
For non-emergency personnel: No action shall be taken involving any personal risk or without suitable training.
Keep unnecessary and unprotected personnel from entering. Do not touch or walk
through spilt material. Put on appropriate personal protective equipment.
For emergency responders: If specialised clothing is required to deal with the spillage, take note of any
information on suitable and unsuitable materials. See also the
information in "For non-emergency personnel".
Environmental precautions: Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air).
Methods and material for containment and cleaning up
Small spill: Move containers from spill area. Vacuum or sweep up material and place in a
designated, labelled waste container. Dispose of via a licensed waste disposal
contractor.
Large spill: Move containers from spill area. Prevent entry into sewers, water courses,
basements or confined areas. Vacuum or sweep up material and place in a
designated, labelled waste container. Dispose of via a licensed waste disposal
contractor.

Handling and storage

Manufacture and use of this chemical intermediate takes place under strictly controlled conditions, as described in Art. 17/18 REACH. The substance is rigorously contained during manufacturing and use and appropriate risk management measures including PPE (i.g. during charging or sampling) are applied. Occupational exposure is reduced to a minimum and well controlled by measurements. A management system covering all general aspects of a chemical production is in place, especially cleaning and maintenance of plants and equipment. An authorisation scheme based on instructions covering the whole process ensures that only trained and authorised staff handles the substance.
Precautions for safe handling
Protective measures: Put on appropriate personal protective equipment. The product is
registered with strictly controlled conditions as defined in Article 17(3) or 18(4) of
regulation (EC) no. 1907/2006 (REACH Regulation) and must therefore be handled
as such. Refer to the industry guidance prepared by Concawe/Cefic/EFCG for advice
on the confirmation of strictly controlled conditions.
Advice on general occupational hygiene: Eating, drinking and smoking should be prohibited in areas where this material is
handled, stored and processed. Workers should wash hands and face before eating,
drinking and smoking. Remove contaminated clothing and protective equipment
before entering eating areas.
Conditions for safe storage, including any incompatibilities: Store in accordance with local regulations. Store in original container protected from
direct sunlight in a dry, cool and well-ventilated area, away from incompatible
materials and food and drink. Keep container tightly closed and
sealed until ready for use. Containers that have been opened must be carefully
resealed and kept upright to prevent leakage. Do not store in unlabelled containers.
Use appropriate containment to avoid environmental contamination.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters
Exposure limit values: Not available.
Recommended monitoring procedures: If this product contains ingredients with exposure limits, personal,
workplace atmosphere or biological monitoring may be required to
determine the effectiveness of the ventilation or other control
measures and/or the necessity to use respiratory protective
equipment. Reference should be made to monitoring standards,
such as the following: European Standard EN 689 (Workplace
atmospheres - Guidance for the assessment of exposure by
inhalation to chemical agents for comparison with limit values and
measurement strategy) European Standard EN 14042 (Workplace
atmospheres - Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents)
European Standard EN 482 (Workplace atmospheres - General
requirements for the performance of procedures for the
measurement of chemical agents) Reference to national guidance
documents for methods for the determination of hazardous
substances will also be required.
Exposure controls
Appropriate engineering controls: In cases of accident and where waste is generated, procedural and/or control
technologies shall be used to minimise emissions and the resulting exposure during
purification or cleaning and maintenance procedures. Procedural and control
technologies shall be used that minimise emission and any resulting exposure. The
substance shall be rigorously contained by technical means during its whole lifecycle
including manufacture, purification, cleaning and maintenance of equipment,
sampling, analysis, loading and unloading of equipment or vessels, waste disposal
or purification and storage.
Individual protection measures
Hygiene measures: Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period.
Appropriate techniques should be used to remove potentially contaminated clothing.
Wash contaminated clothing before reusing. Ensure that eyewash stations and
safety showers are close to the workstation location.
Eye/face protection: Safety eyewear complying with an approved standard should be used when a risk
assessment indicates this is necessary to avoid exposure to liquid splashes, mists,
gases or dusts. If contact is possible, the following protection should be worn,
unless the assessment indicates a higher degree of protection: safety glasses with
side-shields.
Skin protection
Hand protection: Chemical-resistant, impervious gloves complying with an approved standard should
be worn at all times when handling chemical products if product contact cannot be
excluded. After contamination with product change the gloves immediately and
dispose of them according to relevant national and local regulations.
Other skin protection: Personal protective equipment for the body should be selected based on the task
being performed and the risks involved and should be approved by a specialist
before handling this product.
Respiratory protection: If exposure cannot be ruled out, e.g. during product transfer, sampling or
maintenance, a well-fitting respiratory mask conforming to standards or well-fitting
respiratory device conforming to standards must be worn. Respirator selection
must be based on known or anticipated exposure levels, the hazards of the product
and the safe working limits of the selected respirator.
Environmental exposure controls: In some cases, special waste water treatment, fume scrubbers, filters or
engineering modifications to the process equipment will be necessary to reduce
emissions to acceptable levels.

Stability and reactivity

Reactivity: No specific test data related to reactivity available for this product or its ingredients.
Chemical stability: The product is stable.
Possibility of hazardous reactions: Under normal conditions of storage and use, hazardous reactions will not occur.
Conditions to avoid: No specific data
Incompatible materials: No specific data.
Hazardous decomposition products: Under normal conditions of storage and use, hazardous decomposition products
should not be produced.

Disposal considerations

Waste treatment methods
Product
Methods of disposal: The generation of waste shlould be avoided or minimised wherever possible.
Disposal of this product, solutions and any by-products should at all times comply
with the requirements of environmental protection and waste disposal legislation and
any regional local authority requirements. Dispose of surplus and non-recyclable
products via a licensed waste disposal contractor. Waste should not be disposed of
untreated to the sewer unless fully compliant with the requirements of all authorities
with jurisdiction.
Hazardous waste: Within the present knowledge of the supplier, this product is not regarded as
hazardous waste, as defined by EU Directive 2008/98/EC.
Packaging
Methods of disposal: The generation of waste should be avoided or minimised wherever possible. Waste
packaging should be recycled. Incineration or landfill should only be considered
when recycling is not feasible.
Special precautions: This material and its container must be disposed of in a safe way. Empty containers
or liners may retain some product residues. Avoid dispersal of spilt material and