Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to international guideline(s), GLP-compliant, performed in recognized contract research organization, no restrictions, fully adequate for assessment.
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Auto-ignition temperature:
392 °C
Atm. press.:
99 kPa
Remarks on result:
other:

Table 1

Experiment No.

Temperature inside the flask

External Temperature

Ignition

Sample amount

Ignition

delay time

1

99 °C

102 °C

-

100 µl

-

2

199 °C

206 °C

-

100 µl

-

3

300 °C

310 °C

-

100 µl

-

4

301 °C

310 °C

-

500 µl

-

5

350 °C

362 °C

-

100 µl

-

6

350 °C

362 °C

-

500 µl

-

7

400 °C

413 °C

-

100 µl

-

8

400 °C

413 °C

+

500 µl

1.17 min

9

401 °C

413 °C

+

500 µl

1.34 min

10

392 °C

400 °C

+

500 µl

1.17 min

11

381 °C

390 °C

-

500 µl

 

12

385 °C

393 °C

-

500 µl

 

13

389 °C

398 °C

-

500 µl

 

14

389 °C

398 °C

-

500 µl

 

-   - not ignited

-   + ignited

Description of key information

392°C at 99 kPa (EU A.15)

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
392 °C

Additional information

The difference between the pressure measured during the test and the standard pressure is regarded as negligible.