Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: company data

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
Flash point test run according to ERDCO Rapid Tester® Model RT-1 flash point tester manual.
GLP compliance:
no
Type of method:
closed cup
Remarks:
equilibrium

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
- Name of test material (as cited in study report):OS-2600
- Physical state:liquid

Results and discussion

Flash point
Flash point:
> 64 °C
Atm. press.:
other: atmospheric pressure not reported
Remarks on result:
other: Flash point test run according to ERDCO Rapid Tester® Model RT-1 flash point tester manual. Atomospheric pressure not reported.

Any other information on results incl. tables

Flash point test run according to ERDCO Rapid Tester® Model RT-1 flash point tester manual. Flash point atmospheric pressure not reported. Data is consistent with other oxime silane study results.

Applicant's summary and conclusion

Conclusions:
Flash point > 64C
Flash point atmospheric pressure not reported. Data is consistent with other oxime silane study results.