Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Target substance_Flash point_ISO 2719:2002_Pensky-Martens closed cup method: 78 °C at 760 mmHg (101.325 kPa)
Target substance_Flash point_EU Method A.9_equilibrium closed cup method: 117 +/- 2 °C at 101.325 kPa
Read-across substance_Phosphoric acid, mono- and di-(C8-C10) ester, compds. with C12 - 14 amine_Flash point_EU Method A.9_equilibrium closed cup method: 117 +/- 2 °C at 101.325 kPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
78 °C

Additional information

The key study was conducted with the target substance using the Pensky-Martens method (ISO2419:2002) (Anon., 2013). Another study was conducted with the target substance using EU Method A.9 as test guideline (Tremain, 2013a). The flash point of the read-across substance was determined using a Setaflash tester to conduct the closed cup equilibrium method (Tremain, 1998). This procedure was in accordance with EU Method A.9.