Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 January 2015 to 21 April 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Key result
Flash point:
102 °C
Atm. press.:
101 kPa

RESULTS

- The test item combusted with an orange flame and emitted black smoke during the preliminary assessment.

- Results of the flash point determination are shown in Table 3.1 (below).

Table 3.1 – Flash point determination

Temperature (°C)

Observations

0.0

No flash

5.0

No flash

10.0

No flash

15.0

No flash

20.0

No flash

25.0

No flash

30.0

No flash

35.0

No flash

40.0

No flash

45.0

No flash

50.0

No flash

50.0 (fresh sample)

No flash

55.0

No flash

60.0

No flash

65.0

No flash

70.0

No flash

75.0

No flash

80.0

No flash

85.0

No flash

90.0

No flash

95.0

No flash

100.0

No flash

100.0 (fresh sample)

No flash

105.0

A blue flash spread across the sample cup

105.0 (fresh sample)

A blue flash spread across the sample cup

101.0 (fresh sample)

No flash

102.0 (fresh sample)

A blue flash spread across the sample cup

102.0 (fresh sample)

A blue flash spread across the sample cup

100.0 (fresh sample)

No flash

100.0 (fresh sample)

No flash

Atmospheric pressure: 101.0 kPa

Corrected flash point: 102.07 °C

Interpretation of results:
other: Not classified
Conclusions:
The flash point of the test item was determined to be 102 ± 2 °C.
Executive summary:

GUIDELINE

The determination was carried out using a closed cup flash point tester and a procedure designed to be compatible with Method A.9 Flash Point of Commisssion Regulation (EC) No 440/2008 of 30 May 2008.

RESULT

The flash point of the test item was determined to be 102 ± 2 °C.

Description of key information

The flash point of the test item was determined to be 102 ± 2 °C at 101 kPa (EU Method A.9).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
102 °C

Additional information

GUIDELINE

The determination was carried out using a closed cup flash point tester and a procedure designed to be compatible with Method A.9 Flash Point of Commisssion Regulation (EC) No 440/2008 of 30 May 2008.

RESULT

The flash point of the test item was determined to be 102 ± 2 °C at 101 kPa.