Administrative data

Endpoint:
oxidising solids
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Study period:
Between 3 March 2009 and 27 March 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Recently conducted GLP compliant study using the most recent test methods

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): JKY-214
- Physical state: white solid
- Analytical purity: No information
- Lot/batch No.: Y002E
- Expiration date of the lot/batch: No information
- Stability under test conditions: No information. Assumed stable due to no data to the contrary
- Storage condition of test material: room temperature in the dark
- Other:

Results and discussion

Any other information on results incl. tables

The test material structure was assessed and was considered to have no functional groups that are indicative of oxidising properties.

Applicant's summary and conclusion

Conclusions:
Based on the chemical structure of the test material the result of the explosive properties test has been predicted as negative.
Executive summary:

The oxidising potential of the substance has been assessed by considering the chemical structure of the substance in accordance with EU method A17 in compliance with GLP. Based on the chemical structure of the test material the result of the oxidising properties test has been predicted as negative.