Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
(4aR,4bS,6aS,7S,7aS,8aS,8bR,8cR)-7-[2-(1,3-dioxolan-2-yl)ethyl]-2-methoxy-4a,6a-dimethyl-3,4,4a,4b,5,6,6a,7,7a,8,8a,8b,8c,9-tetradecahydrocyclopropa[4,5]cyclopenta[1,2-a]phenanthren-7-ol
EC Number:
618-226-9
Cas Number:
889652-22-6
Molecular formula:
C26H38O4
IUPAC Name:
(4aR,4bS,6aS,7S,7aS,8aS,8bR,8cR)-7-[2-(1,3-dioxolan-2-yl)ethyl]-2-methoxy-4a,6a-dimethyl-3,4,4a,4b,5,6,6a,7,7a,8,8a,8b,8c,9-tetradecahydrocyclopropa[4,5]cyclopenta[1,2-a]phenanthren-7-ol
Test material form:
solid: crystalline

Results and discussion

Flammable solidsopen allclose all
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: non-flammable
Test procedure:
burning rate test over 100 mm length
Remarks on result:
not measured/tested
Remarks:
Burning rate test was not performed because of the result of the preliminary test.
Pyrophoric solids
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
According to manufacturing / handling experience.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
According to manufacturing / handling experience.

Applicant's summary and conclusion