flammability
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Justification for type of information:
The substance does not contain structural components associated with pyrophoricity and/or flammability on contact with water mentioned in the Guidance on information requirements and chemical safety assessment Chapter R.7a: Endpoint specific guidance, chapter R.7.1.10.3, page 123. Therefore, it can be concluded that the substance exhibit no risk for pyrophoricity and/or flammability on contact with water. No study is required.

Description of key information

The substance does not contain structural components associated with pyrophoricity and/or flammability on contact with water mentioned in the Guidance on information requirements and chemical safety assessment Chapter R.7a: Endpoint specific guidance, chapter R.7.1.10.3, page 123. Therefore, it can be concluded that the substance exhibit no risk for pyrophoricity and/or flammability on contact with water. No study is required.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification