Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5-6 January 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Data have been generated according to current internationally recognised study guidelines and in accordance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:
The test substance is not explsoive.
Executive summary:

The explosivity test was conducted according to the EU A14 test method in compliance with GLP. The substance was assessed to the effect of friction (BAM friction test), shock (BAM fall hammer test) and flame (Koenen steel tube test). Under the conditions of the test, the substance is not explosive.

Description of key information

The explosivity test was conducted according to the EU A14 test method in compliance with GLP. The substance was assessed to the effect of friction (BAM friction test), shock (BAM fall hammer test) and flame (Koenen steel tube test). Under the conditions of the test, the substance is not explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

The explosivity test was conducted according to the EU A14 test method in compliance with GLP. The substance was assessed to the effect of friction (BAM friction test), shock (BAM fall hammer test) and flame (Koenen steel tube test). Under the conditions of the test, the substance is not explosive.