Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
None
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Principles of method if other than guideline:
None
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
mass based distribution
Specific details on test material used for the study:
None
Mass median aerodynamic diameter:
161.306 µm
Percentile:
other: L10
Mean:
18.983 µm
Remarks on result:
other: Standard deviation not available
Key result
Percentile:
other: L50
Mean:
161.306 µm
Remarks on result:
other: Standard deviation not available
Percentile:
other: L90
Mean:
424.23 µm
Remarks on result:
other: Standard deviation not available

None

Conclusions:
The median particle size (L50) of FAT 40000 was found to be 161.306 µm.
Executive summary:

The particle size of FAT 40000 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Lased diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 18.983, 161.306 and 424.230 µm, respectively. Hence, the median particle size (L50) of FAT 40000 was determined to be 161.306 µm.

Description of key information

The median particle size (L50) of FAT 40000 was determined to be 161.306 µm.

Additional information

The particle size of FAT 40000 was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Lased diffraction method was used for this purpose. Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 18.983, 161.306 and 424.230 µm, respectively. Hence, the median particle size (L50) of FAT 40000 was determined to be 161.306 µm.