Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 23, 2007 - July 26, 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: study conform with Directive EEC 92/69, A.2, OECD Guideline No. 103

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Details on test material:
Identity: AES
Batch: LSF7
Purity: 80.3%
Appearance: Solid
Expiration date: February 15, 2008
Storage: In the refrigerator at about 4 °C

Results and discussion

Boiling point
Boiling pt.:
25 - 400 °C
Atm. press.:
99.2 kPa
Decomposition:
yes
Decomp. temp.:
150 °C

Applicant's summary and conclusion

Conclusions:
AES melted and decomposed (starting at about 150°C) before boiling occured.
Executive summary:

Between 141 °C and 148 °C the test item rose in the capillary tube and bubbled for some seconds. However a current stream of bubbles could not be observed. Above 150 °C the melt evolved black spots and later changed to greyish. At about 300 °C the test item turned orange. At about 350 °C black spots were observed. After the test, a dark orange and partly black residue remained.