Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of necessary first-aid measures

General advice : Show this safety data sheet to the doctor in attendance. First aider needs to protect himself. Place affected clothing in a sealed bag for subsequent decontamination.

Inhalation : not applicable

Skin contact : Take off contaminated clothing and shoes immediately. Wash off with plenty of water. Wash immediately and thoroughly for a prolonged period (at least 15 minutes). Call a physician if irritation develops or persists.

Eye contact : Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get immediate medical advice/ attention.

Ingestion : Do NOT induce vomiting. Rinse mouth with water.

Fire-fighting measures

Extinguishing media

Suitable extinguishing media : Water spray Foam, Carbon dioxide (CO2)

Unsuitable extinguishing media : High volume water jet

Special hazards arising from the substance or mixture

Specific hazards during firefighting : Aqueous liquid. Does not present any particular risk in the event of a fire. Nevertheless, following the evaporation of water,the residue may burn: with the release of toxic gas.

Advice for firefighters

Special protective equipment for firefighters : Wear self contained breathing apparatus for fire fighting if necessary. Personal protective equipment comprising: suitable protective gloves, safety goggles and protective clothing

Further information : Collect contaminated fire extinguishing water separately. This must not be discharged into drains.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Avoid contact with the skin and the eyes. Do not allow uncontrolled discharge of product into the environment. Personal protective equipment Wear suitable protective clothing. Wear suitable gloves. Safety glasses, Face-shield, Stop the leak. Turn leaking containers leak-side up to prevent the escape of liquid.

Environmental precautions : Dam up. Prevent product from entering drains.

Methods for Cleaning or Taking Up

Decontamination/cleaning : Contain spillage, soak up with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and transfer to a container for disposal according to local / national regulations (see section 13). Keep in suitable, closed containers for disposal.

Decontamination/cleaning : Wash off with plenty of water. Recover the cleaning water for subsequent disposal.

Disposal : Dispose of in accordance with local regulations.

Additional advice : Material can create slippery conditions.

Handling and storage

Handling

Technical measures : Does not require any specific or particular measures.

Advice on safe handling and usage : Handle in accordance with good industrial hygiene and safety practice.

Storage

Technical Measures for storage : Take all necessary measures to avoid accidental discharge of products into drains and waterways due to the rupture of containers or transfer systems.

Storage conditions Recommended : Stable under normal conditions. Keep container tightly closed. Keep in a well-ventilated place. Keep in a dry, cool place. Keep away from heat and sources of ignition. Keep away from incompatible materials to be indicated by the manufacturer

Incompatible products : Strong acids, Strong bases, Strong oxidizing agents, Strong reducing agents.

Packaging Measures

Packaging Measures : Store in original container.

Packaging materials - Recommended : Plastic materials.

Packaging materials - To be avoided : Uncoated metals

Storage temperature : 10 - 40 °C

Other data : May aggravate the corrosion of metals in aqueous solution.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
not regulated for the concentration considered in water.
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
not regulated for the concentration considered in water.
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
not regulated for the concentration considered in water.
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
not regulated for the concentration considered in water.
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control measures

Engineering measures : Avoid splashes. Provide adequate ventilation. Extract at emission point.

Personal protective equipment

Respiratory protection : Use a respirator with an approved filter if a risk assessment indicates this is necessary.

Hand protection : PVC gloves, Where there is a risk of contact with hands, use appropriate gloves, Gloves must be inspected prior to use.

Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.

Eye protection : Safety glasses with side-shields

In case of contact through splashing: Safety glasses with side-shields Face-shield

Skin and body protection : Protective suit Choose body protection according to the amount and concentration of the dangerous substance at the work place.

Hygiene measures : Emergency equipment immediately accessible, with instructions for use. Ensure that eyewash stations and safety showers are close to the workstation location.

Use clean, well-maintained personal protection equipment. Wash hands before breaks and at the end of workday. When using do not eat, drink or smoke.

Protective measures : The protective equipment must be selected in accordance with current CEN standards and in cooperation with the supplier of the protective equipment. Selection of appropriate personal protective equipment should be based on an evaluation of the performance characteristics of the protective equipment relative to the task(s) to be performed, conditions present, duration of use, and the potential hazards and/or risks that may occur during use.

General advice : Dam up. Prevent product from entering drains.

Stability and reactivity

Chemical stability : Stable under normal conditions.

Hazardous reactions

Materials to avoid : Strong acids, Strong bases, Strong oxidizing agents, Strong reducing agents.

Decomposition products : On combustion or on thermal decomposition (following the evaporation of water) releases: nitrogen oxides (NOx). (Carbon oxides (CO + CO2)).

Disposal considerations

Product Disposal

Prohibition : Should not be released into the environment.

Advice on Disposal : Dispose of in accordance with local regulations.

Advice on cleaning and disposal of packaging

Measures for waste avoidance. : Do not dispose of the product at a rubbish tip.

Advice : Completely empty the packaging prior to decontamination. Carefully drain and then steam clean.

Reason for waste disposal : Recycle following cleaning. Dispose of contents/ container to an approved waste disposal plant.