Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 26-08-2015 to 02-09-2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test method is according to ASTM D6450-99 and it is not GLP.
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D6450-99
Deviations:
no
GLP compliance:
no
Type of method:
other: Continuously Closed Cup (CCCFP) Tester
Flash point:
ca. 126 °C
Atm. press.:
101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test material was determined to be 126 ºC.
Executive summary:

The flash point of the test material was determined according to method ASTM D6450-99. The flash point is 126 ºC.

Description of key information

The flash point of the test material was determined according to method ASTM D6450-99. The flash point is 126 ºC.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
126 °C

Additional information