Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 23 June 2015 and 24 June 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Not applicable
Qualifier:
according to
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. certificate)
Contact with:
other: Not applicable
Key result
Sample tested:
test mixture as specified
Parameter:
other: Structural analysis
Remarks on result:
other: There are no structural alerts within the chemical structure of the test item.
Remarks:
There are no structural alerts within the chemical structure of the test item.

There are no structural alerts within the chemical structure of the test item.

Interpretation of results:
GHS criteria not met
Conclusions:
Based on the chemical structure of the test item, the result for the oxidising properties has been predicted negative.
Executive summary:

Oxidizing Properties (Liquids).Predicted negative based on the chemical structure of the test item, using a procedure designed to be compatible with Method A21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

Oxidizing Properties (Liquids).Predicted negative based on the chemical structure of the test item, using a procedure designed to be compatible with Method A21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification