Registration Dossier

Administrative data

Endpoint:
relative density
Remarks:
Other density types indicated (migrated information): density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
October 1, 2014 - November 28, 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-compliant study in accordance with EC A.3, OECD 109 and EPA OPPTS 830.7300.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
(2008)
Deviations:
no
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
(2012)
Deviations:
no
Qualifier:
according to
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Version / remarks:
(2002)
Deviations:
no
GLP compliance:
yes
Type of method:
air comparison pycnometer (for solids)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): L 131
- Appearance: Faint light-green powder

Results and discussion

Densityopen allclose all
Type:
density
Density:
3.7 g/cm³
Temp.:
20 °C
Remarks on result:
other: Mean of 3.706 and 3.702 g/cm3
Type:
relative density
Density:
3.7
Temp.:
20 °C

Any other information on results incl. tables

Accuracy: < 0.02 g/cm3

Applicant's summary and conclusion

Conclusions:
In a GLP-compliant study in accordance with EC A.3, OECD 109 and EPA OPPTS 830.7300 using a gas comparison pycnometer, the relative density of the substance at 20°C has been determined as 3.70.