Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to EU/OECD-guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes (incl. certificate)
Type of method:
thermal analysis

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing point
Decomposition:
yes
Decomp. temp.:
172.5 °C
Remarks on result:
other: The substance had no melting point. The average onset temperature of the decomposition was 172.5°C.

Applicant's summary and conclusion

Conclusions:
The substance had no melting point.