Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 239-362-1 | CAS number: 15332-99-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
Key value for chemical safety assessment
Skin sensitisation
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not sensitising)
- Additional information:
Tris(isopropenyloxy)(vinyl)silane has been tested in a guinea-pig maximisation (Buehler) study conducted according to OECD 406 and in compliance with GLP. None of the animals challenged for 6 hours to the test item or the negative control showed any evidence of sensitisation at either 24 or 48 hours after removing the patch (BSL Bioservice 2015d).
The current accepted and preferred method for skin sensitisation testing according to the REACH legislation (EC No 1907/2006) and CLP Regulation (EC No 1272/2008) is the murine local lymph node assay (LLNA). A validated test method, OECD TG 429 (OECD 2002) is available for the LLNA. The guideline acknowledges the limits of the LLNA, and states that there are instances where ‘test substance classes or substances containing functional groups shown to act as potential confounders’ make the use of guinea pig tests more appropriate. It is concluded that the LLNA is not applicable where the properties of the test material cause interference in the accuracy of the LLNA (OECD 2002). The statement in the OECD TG 429 is given with reference to the findings of Basketter et al. (2009a), who demonstrated false positives in silicon based substances which had previously been demonstrated to be non-sensitisers in the guinea pig maximisation test (GPMT). The importance of available evidence from guinea pig results, consideration of chemical reactivity, epidermal bioavailability and clinical and experimental human data are emphasised as central to reaching appropriate regulatory decisions for substances which have been shown to fall outside the specificity of the LLNA (Basketter et al., 2009b). The non-applicability of the LLNA for silicone based substances has also been demonstrated by Petry et al. (2012). The sensitisation potential of polyfunctional silicone materials was tested in a comparative study investigating the GPMT and the LLNA assays, which found the five tested substances to be negative in the GPMT whereas they were concluded to be weak to moderate skin sensitisers in the LLNA (Petry et al., 2012).
References:
Basketter D, Ball N, Cagen S, Carillo JC, Certa H, Eigler D, Garcia C, Esch H, Graham C, Haux C, Kreiling R, Mehling A (2009a). Application of weight of evidence approach to assessing discordant sensitisation datasets: implication for REACH. Reg. Toxicol. Pharmacol.,55, 90-96.
Basketter D, McFadden JF, Gerberick F, Cockshott A, Kimber I (2009b) Nothing is perfect, not even the local lymph node assay: a commentary and the implications for REACH. Contact Dermatitis, 60, 65-69.
Petry, T., Bosch, A., Coste, X., Dupuis, V., Eigler, D., Germain, P. (2012). An assessment of the skin sensitisation hazard of a group of polyfunctional silicones using a weight of evidence approach. Regulatory Toxicology and Pharmacology, 64, 305-314.
Justification for selection of skin sensitisation endpoint:
The selected study was conducted according to an appropriate OECD guideline and in compliance with GLP.
Respiratory sensitisation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Justification for classification or non-classification
Based on the available studies on skin sensitisation, tris(isopropenyloxy)(vinyl)silane does not require classification according to Regulation (EC) No 1272/2008.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.