Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013-05-10
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
other: Rolling Ball Viscosimeter
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
15.352
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
5.968
Conclusions:
Using a rolling ball viscosimeter, viscosities of

15.352 ± 0.001 mPa * s at 20.00 ± 0.02 °C
and
5.968 ± 0.019 mPa * s at 40.00 ± 0.00 °C

were measured.
Executive summary:

The viscosity of 3-Methylpyrazolwas determined according to OECD guideline 114 as 15.352 ± 0.001 mPa * s at 20.00 ± 0.02  C and as 5.968 ± 0.019 mPa * s at 40.00 ±0.00 C. Both values are the means of two triplicate determinations ± standard deviation for each temperature. As the measured RSDs were 0.01 % for the determination at 20 °C and 0.32% for the determination at 40 °C, the validity criterion for ball no. 2 is met for both determinations. Measurements were performed at 20.00±0.02 °C respectively 40.00 ± 0.00 °C.

Description of key information

Using a rolling ball viscosimeter, viscosities of

15.352 ± 0.001 mPa * s at 20.00 ± 0.02 °C

and

5.968 ± 0.019 mPa * s at 40.00 ± 0.00 °C

were measured.

Key value for chemical safety assessment

Viscosity:
15.352 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The reported study is GLP compliant and has Klimisch score 1.