Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: In case of accident by inhalation: remove casaulty to fresh
air and keep at rest. Call a physician.
Emergency measure - Eyes: Rinse with plenty of water and consult a physician.
Emergency measure - Skin: Remove contaminated clothing immediately.

Wash off with soap and plenty of water and consult a
physician.
Emergency measure - Ingestion: Do not induce vomiting. Rinse mouth with water. Consult a
physician.

Fire-fighting measures

Recommended extinguishing agent: water spray, foam, carbon dioxide, dry powder, sand

Product arising from burning: carbon monoxide, carbon dioxide, water, hydrogen chloride

Product determined by test: N

Protective equipment: In case of fire wear self contained breathing apparatus.


Use water spray to cool unopened containers.

Accidental release measures

Emergency measures in case of spillage: Avoid any contact with spilt product or contaminated
surfaces.

Wear personal protective equipment (see 2.3.10).

Unprotected persons must be kept away.


Soak up or pump off spillage and collect in suitable

tightly closed waste containers which have to be labelled
according to TRGS 201.

Dispose according to local regulations.


Do not flush into surface water or sanitary sewer systems.

Handling and storage

Handling: Working procedures must always be designed so that contact
with the skin and eyes is excluded. Avoid inhalation of the
substance.


As far as possible, closed equipment has to be used during
transfer and metered feeding as well as during sampling.

In the case of handling the substance in open systems,
extract any vapours or aerosols which might form directly

at the point of origin.

If technical extraction or ventilation measures are not
possible or are insufficient, suitable respiratory
protection (e.g. filter apparatus, Filter ABEK-P2) must be
worn.

Even if skin contact is only possible for short periods,
tested protective gloves (e.g. made of nitrile rubber) and
suitable protective clothing must be worn.

Safe eye protection (e.g. tight-fitting safety goggles) is
absolutely essential.


Adequate washing facilities and conspicuously labelled
eye-douche stations should be provided in the immediate
vicinity of the working area. After contact with the skin,
the affected parts of the body should be immediately
thoroughly cleaned using soap and plenty of water.
Contaminated clothing must be changed immediately. Special
skin-protection and skin-care measures are recommended.

A skin-protection plan must be drawn up.


If vapours or aerosols can develop, due to the potential
explosion risk, potential sources of ignition should be
removed out of the working area. In addition, measures
should be taken to prevent electrostatic discharges.

Storage: Apply the VCI concept for the Mixed Storage of Chemicals.
Store in original container.


Keep container tightly closed.

Do not store in heat or direct sunlight.

Keep in a dry, cool and well-ventilated place.

Keep away from food, drink and animal feeding stuffs.

Packaging of the substance and or preparation: Drums, 200L

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: UN-Nr. 3265
Transport: Internal transport:

Use tightly closed and unbreakable containers.


Secure container from falling.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: reaction with water

Chemical reaction with water: organic acid chlorides react with water under the formation
of hydrochlorid acid.

Dust explosion: not applicable

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: The substance will be used as an intermediate in the
chemical industry and can not be recycled.

Industry - Possibility of neutralisation: none known

Industry - Possibility of destruction: controlled discharge: Incineration.

Industry - Possibility of destruction - incineration: Industrial incinerator with gas scubber.

Industry - Possibility of destruction - water purification: Treatment in an industrial sewage water treatment plant.

Public at large - Possibility of recovery/recycling: Not applicable, industrial intermediate only.