Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammability
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: expert judgement
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:

Data source

Materials and methods

Test guideline
Guideline:
other: Expert judgement
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Based on chemical structure water reactivity is not to be expected.

Applicant's summary and conclusion