Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
other: the vapor pressure balance method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: Liquid
Details on test material:
Batch SC00008199
Purity 99.5%
Expiry date 19 August 2016

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
12 Pa

Applicant's summary and conclusion

Conclusions:
The vapor pressure of the test item has been determined to be 12 Pa at 25 ºC.