Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
Batch SC00008199
Purity 99.5%
Expiry date 19 August 2016

Results and discussion

Flash point
Flash point:
94 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
The flash point of the test item has been determined to be 94 ± 2 °C.