Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: Guidance Document on the Determination of Particle Size Distribution, Fibre Length and Diameter Distribution of Chemical Substances, EUR 20268 EN (2002).
Qualifier:
according to guideline
Guideline:
other: Standard ISO 13320: 2009 Particle size analysis – Laser diffraction methods, First edition 2009-10-01.
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Constituent 1
Reference substance name:
Acetic acid, 4-nitrophenyl ester
IUPAC Name:
Acetic acid, 4-nitrophenyl ester
Constituent 2
Chemical structure
Reference substance name:
4-nitrophenyl acetate
EC Number:
212-593-5
EC Name:
4-nitrophenyl acetate
Cas Number:
830-03-5
Molecular formula:
C8H7NO4
IUPAC Name:
4-nitrophenyl acetate
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
- Name of test material (as cited in study report): 4-Nitrophenyl Acetate

- Physical state: solid
- Analytical purity: 95 % w/w
- Impurities (identity and concentrations):
Phenol <5.0 % (w/w)
4-nitrophenol <5.0 % (w/w)
Acetic acid <1.0 % (w/w)
Water <5.0 % (w/w)

- Lot/batch No.: 201409
- Expiration date of the lot/batch: unlisted

- Storage condition of test material: During the study the test substance was stored in closed
container in the dark at laboratory temperature.

Results and discussion

Mass median aerodynamic diameter:
30.6 µm
Particle sizeopen allclose all
Percentile:
D50
Mean:
30.6 µm
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D90
Mean:
48.8 µm
St. dev.:
2.4
Percentile:
D10
Mean:
17.5 µm
St. dev.:
0.6

Any other information on results incl. tables

 Determination   Median (mm)   Diameter on Cumulative 90%(mm)   Diameter on Cumulative 10%(mm)   Span(-) 
 Final result   30.6   48.8   17.5   1.0 
 Extended uncertainty   1.2   2.4   0.6   - 