Description of key information

Key study: Test method OECD 110 and CIPAC MT 170. GLP Study. The particle size distribution of the test item was: over 1400µm: 3.08%; between 1000-1400µm: 4.82%; between 710-1000µm: 7.22%; between 500-710µm: 11.97%; between 250-500µm: 28.84%; between 125-250µm: 29.00%; between 75-125µm: 12.49%; between 45-75µm: 2.41% and under 45µm: 0.19%.

Additional information

Key study: A Particle Size Distribution study was performed according to OECD Guideline 110 and CIPAC MT 170. GLP study.