Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to EU/OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Version / remarks:
(1981)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

For thermal stability study

Test substance thermally stable:
yes

Any other information on results incl. tables

Two DSC-measurements in closed glass crucibles showed an endothermal effect in the temperature range of 85 - 115 °C followed by two exothermal effects in the temperature ranges of 220 - 300 °C and 300 - 435 °C with an overall energy of 1273 J/g and 1116 J/g, respectively.

Applicant's summary and conclusion

Conclusions:
The test item is thermal stable.