Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2, 2002 - February 24, 2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: NF ISO 2591-1(1989)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: NFX11-507 (1989)
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
no
Remarks:
(only the preliminary test was conducted according to GLP principles, not the main test)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D50
Mean:
452.75 µm
Remarks on result:
other: Test #1
Percentile:
D50
Mean:
447.991 µm
Remarks on result:
other: Test #2

Preliminary test

- Dry sieving was not appropriate as the test item blocked the apertures of the test sieve

- Wet sieving was not possible as the test item was not wettable with water

Main test

-Particle Size Distribution Test #1:
99.89% >19.9 µm
99.34% >29.9 µm
98.61% >39.23 µm
97.35% >51.47 µm
94.55% >77.33 µm
92.56% >101.4 µm
90.02% >152.4 µm
88.32% >200 µm
83.9% >300.5 µm
70.1% >394.2 µm
50.47% >451.5 µm
26.18% >517.2 µm
10.52% >592.3 µm
1.57%  >771.1 µm

Median diameter: 452.750 µm

Mean diameter: 430.942 µm

-Particle Size Distribution Test #2:

99.88% >26.11 µm
99.72% >29.9 µm
99.14% >39.23 µm
98.03% >51.47 µm
95.75% >77.33 µm
94.75% >101.4 µm
94.09% >152.4 µm
93.72% >200 µm
90.77% >300.5 µm
71.18% >394.2 µm
48.69% >451.5 µm
26.94% >517.2 µm
12.46% >592.3 µm
1.68%  >771.1 µm

Median diameter: 447.991 µm

Mean diameter: 448.468 µm

Conclusions:
The particle size distribution of the substance was determined in duplicate, using laser diffraction analysis. The median D50 was 452.750 µm and 447.991 µm. All particles were >17 µm and approximately 92% of all particles were >100 µm.

Description of key information

The particle size distribution of the substance was determined twice. The median D50 was 452.750 µm and 447.991 µm. All particles were >17 µm and approximately 92% of all particles were >100 µm.

Additional information

The particle size distribution of the substance was determined using laser diffraction analysis.