Registration Dossier

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 - 25 Nov 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was done in accordance with EU guidance and under GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
not applicable
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): DVE-3, 1,1,2,2,3,3-hexafluoro-1,3-bis[(trifluoroethenyl)oxy]propane
- Physical state: clear, colourless liquid
- Analytical purity:98.8%
- Storage condition of test material: room temperature (10-30 °C), dry, under nitrogen, protected from light

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
190 °C
Atm. press.:
1 014.7 - 1 018.4 hPa
Remarks on result:
other:

Applicant's summary and conclusion

Conclusions:
The auto-flammability temperture of DVE-3 was reported as 190 °C according to EU Method A.15. The ambient pressure during the test was 1014.7 hPa to 1018.4 hPa.
Executive summary:

The auto-flammability of DVE-3 was determined according to EU Method A.15 under GLP; therefore, the study is considered reliable without restrictions. It is suitable for Risk Assessment and Classification & Labelling.