Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From October 21, 2015 to October 26, 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Contact with:
powdered cellulose
Duration of test (contact time):
2 min
Sample tested:
test mixture as specified
Remarks:
10%, 20%, 30%, 40%, 50%, 60%, 70%, 80% and 90%
Parameter:
maximum burning rate
Remarks on result:
mixture does not ignite and burn

Table 1. Preliminary test

Test Item

Barium nitrate/Sample

g

Powdered cellulose (Combustible substance)

g

Test Results

s

Reference mixture

3.00

2.00

53.56

Sample mixture

2.00

1.00

/

Table 2. Train Test

Ratio of sample to combustible substance

10%

20%

30%

40%

50%

60%

70%

80%

90%

Burning time (s)

 

/

/

/

/

/

/

/

/

Burning rate (mm/s)

/

/

/

/

/

/

/

/

/

Reference mixture

Barium nitrate: Powdered cellulose = 3 : 2

Burning time: 164.37 s

Burning rate: 1.22 mm/s

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU A.17 test method, CJ306 is not considered as an oxidizing substance. Therefore, CJ306 was not met GHS criteria.
Executive summary:

The oxidizing property of CJ306 was determined according to EC REGULATION No 440/2008 Annex A.17 Oxidizing Properties (Solids). The result of preliminary test showed that the combustibility did not sustain, so the full train test is necessary. In train test, the result showed that the piles of sample cellulose-mixtures containing 10 to 90 % weight did not ignited in 2 min. Therefore, CJ306 is not considered as an oxidizing substance.

Description of key information

CJ306 is not considered as an oxidizing substance (EC A.17).

 

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

The result of preliminary test showed that the combustibility did not sustain, so the full train test is necessary. In Train Test, the result showed that the piles of sample cellulose-mixtures containing 10 to 90 % weight did not ignited in 2 min. Therefore, CJ306 is not considered as an oxidizing substance.

Justification for classification or non-classification