Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study according to international accepted guidelines but not GLP compliant.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report Date:
2014

Materials and methods

Test guideline
Qualifier:
equivalent or similar to
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
UN Recommendation on the Transport of Dangerous Goods
Deviations:
no
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
Test item: Levodione
CAS number: 21800-83-9
Batch number: 242027N
Physical state: Solid, crystalline powder
Colour: White
Storage: At a temperature of 15 to 30 °C

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: The burning rate test was not performed because of the result of the preliminary test.
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: According to manufacturing/handling experience.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record. | Remarks: | Additional remarks: According to manufacturing/handling experience.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.| Remarks: | Additional remarks: According to company laboratory instructions.

Any other information on results incl. tables

In the vicinity of the heat source in the high-temperature zone the substance was melted not on the entire surface. White smoke formed during melting. The melted surface was burning with a large flame next to the heat source. After removing the heat source the combustion disappeared immediately.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information After removing the heat source the combustion disappeared immediately.
Conclusions:
The substance (levodione) should not be considered as flammable und no further testing is required. According to the GHS criteria the measured substance cannot be classified.