Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
03 NOV 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes (incl. QA statement)
Type of method:
rotational viscometer (dynamic)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
28.1

 Results of measured apparent viscosity:

Test No.

Temperature

Rotational frequency

Apparent viscosity

Difference between two measurements

Average viscosity

°C

min-1

mPa*s

%

mPa*s

1.

20

100

28.1

0.0

28.1

2.

20

28.1

 

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
04 NOV 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes (incl. QA statement)
Type of method:
rotational viscometer (dynamic)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
23.5

Results of measured apparent viscosity:

Test No.

Temperature

Rotational frequency

Apparent viscosity

Difference between two measurements

Average viscosity

°C

min-1

mPa*s

%

mPa*s

1.

20

100

23.5

0.0

23.5

2.

20

23.5

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
29 OCT 2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: ISO 3104
Principles of method if other than guideline:
Capillary method (Ubbelohde)
GLP compliance:
no
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
28.6
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
13.3

Description of key information

23.5 - 28.1 mPa*s at 20 °C (OECD 114)

28.6 mm²/s at 20 °C (ISO 3104)

13.3 mm²/s at 40 °C (ISO 3104)

28.6 mm²/s at 20 °C

28.6 mm²/s at 20 °C, 13.3 mm²/s at

40 °C (ISO 3104)

Key value for chemical safety assessment

Viscosity:
28.1 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The data refer to measurements of substances of various single degrees of ethoxylation (EO = 2 and EO = 1). For a general ethoxylation degree of < 2.5 EO, a weight of evidence approach is applied.