Registration Dossier

Administrative data

Endpoint:
eye irritation
Data waiving:
other justification
Justification for data waiving:
other:

Data source

Materials and methods

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Applicant's summary and conclusion

Interpretation of results:
corrosive
Remarks:
Migrated information Criteria used for interpretation of results: OECD GHS
Conclusions:
pH-value of 2.5 w/w % solution of SnSO_4 is < 2. So it is to assume that the substance causes corrosive or severe irritant effect in eyes.