Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Remarks:
very poor documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1998
Report date:
1998

Materials and methods

Principles of method if other than guideline:
Testing of thermal and mechanical (shock) sensitivity

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2'-[(3,3'-dichloro[1,1'-biphenyl]-4,4'-diyl)bis(azo)]bis[N-(2,4-dimethylphenyl)-3-oxobutyramide]
EC Number:
225-822-9
EC Name:
2,2'-[(3,3'-dichloro[1,1'-biphenyl]-4,4'-diyl)bis(azo)]bis[N-(2,4-dimethylphenyl)-3-oxobutyramide]
Cas Number:
5102-83-0
Molecular formula:
C36H34Cl2N6O4
IUPAC Name:
2,2'-[(3,3'-dichlorobiphenyl-4,4'-diyl)didiazene-2,1-diyl]bis[N-(2,4-dimethylphenyl)-3-oxobutanamide]
Test material form:
solid: nanoform

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive under influence of flame
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

Test for thermal and mechanical (shock) sensitivity showed no reaction of the test item. Testing for friction sensitivity was not conducted.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item did not show explosive properties in studies for thermal and mechanical (shock) sensitivity