Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-like

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup

Test material

Results and discussion

Flash point
Flash point:
135.5 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
The test item shows a flash point at a temperature of 135.5°C (1013 mbar)