Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil/sewage sludge
Radiolabelling:
no
Details on study design: HPLC method:
HPLC parameters:
- HPLC system: Agilent Technologies 1050/1100, incorporating autosampler and workstation
- Column: Hypersil Gold CN (150 x 4.6 mm id)
- Column temperature: 35 degrees C
- Mobile phase: methanol:water (55:45 v/v_
- pH of mobile phase: 7.0 adjusted with 0.1M sodium hydroxide
- Flow-rate: 1.0 ml/min
- Injection volume: 10 ul
- UV detector wavelength: 210 nm
Type:
Koc
Value:
177.83
Temp.:
35 °C
Remarks on result:
other: Assumed to have been determined at NTP
Type:
log Koc
Value:
2.25
Temp.:
35 °C
Remarks on result:
other: Assumed to have been determined at NTP
Details on results (HPLC method):
See table 1 (in 'remarks and results including tables and figures' field) for retention times, capacity factors and log Koc values for each sample.
Transformation products:
not measured

Table 1. Retention time, capacity factors and log Koc values for each sample.

Injection Retention time (minutes) Capacity factor (k) Log K Log10Koc Mean Log10Koc
1 2.939 0.425 -0.372 2.25 2.25
2 2.938 0.424 -0.372 2.25
Validity criteria fulfilled:
yes
Conclusions:
Under the conditions of this study, the adsorption coefficient of the test item is 177.83 (log koc = 2.25)

Description of key information

The adsorption coefficient (Koc) was determined by application of EC Method C19/OECD 121 (HPLC method).

Key value for chemical safety assessment

Koc at 20 °C:
177.83

Additional information

Under the conditions of this study, the adsorption coefficient was 177.83: Log Koc = 2.25 (determined at 35 degrees C using HPLC).

[LogKoc: 2.25]