Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Description of key information

Flammability (EU method A.10):

The test substance did not burn over a length of 200 mm within 4 minutes. Therefore the full test programme (main test) was not carried out and the test substance is not classified as "highly flammable", according to the guideline.

Flammability (contact with water, EU method A.12):

The practical experience of the sponsor and the test facility shows that no gases are developed when the test substance is in contact with water. The test substance is therefore regarded as not being flammable in contact with water.

Pyrophoric properties (EU method A.13):

The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing. The test substance is therefore regarded as not being pyrophoric.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

The test substance is not classified as flammable according to EU Method A.10.

The test substance is regarded as not being flammable in contact with water.