Registration Dossier

Diss Factsheets

Environmental fate & pathways

Phototransformation in air

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
phototransformation in air
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Guideline draft (Photochemical Oxidative Degradation in the Atmosphere)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test performance:
The test material has been determined to have a molar absorption coefficient (ε) < 10 1/cm dm³ 1/mol at a wavelength of 290 nm. Therefore, no photochemical degradation study was required.
Parameter:
max epsilon
Value:
6.07 1/cm dm³ 1/mol

Description of key information

Key value for chemical safety assessment

Half-life in air:
19 h

Additional information