Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From July 14,2010 to July 15,2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well described GLP compliant study conducted to recognized international test guidelines
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Specific details on test material used for the study:
Fatty acids, C6-24 and C6-24-unsatd., Me esters, distn. residues- Physical state: black , brown semisolid- Analytical purity:100% - Storage condition of test material: room temperature- Solubility: < 10% in water, soluble in acetone, hexane and dichloromethane
Key result
Flash point:
ca. 118.5 °C
Atm. press.:
ca. 1 013 mBar
Conclusions:
The test item shows a flash point at a temperature of 118.5 °C (1013 mbar) according to the definition in the EEC-directive 92/69/EEC, method A.9. (by means of Pensky-Martens apparatus, according to DIN EN ISO 2719).
Executive summary:

The flash point of test item was determined in accordance with the test method A.9. "Flash Point" as described in the Official Journal of the European Communities L383A

Description of key information

118.5 °C (1013 mbar)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
118.5 °C

Additional information

The test item shows a flash point at a temperature of 118.5 °C (1013 mbar) according to the definition in the EEC-directive 92/69/EEC, method A.9. (by means of Pensky-Martens apparatus, according to DIN EN ISO 2719).